DIOD-TRK (DIOD Trunk)
Issue 5 October 2002
1061
555-233-119
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use the status trunk
command to determine when the port is available for testing.
1. Retry the command at one minute intervals a maximum of 5 times.
1018
ABORT
Test has been disabled via administration.
1. Verify that the
Maintenance Tests?
field on the Trunk Group
Form is set to n. To enable the test, issue the change trunk-group x
command where “x” equals the number of the trunk group to be tested.
Then change the entry in the
Maintenance Tests?
field on the
form to y.
1005
ABORT
Trunk has been administered as incoming-only; or DID trunk group type;
dial tone can only be obtained on outgoing trunks. This is a normal
condition.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
Trunk was seized, but dial tone could not be detected.
1. Check for errors on TONE-BD or TONE-PT. Clear any errors found and
repeat test.
2. If error has still not cleared, refer problem to CO.
2002
FAIL
Seizure portion of test failed due to hardware problem. Fault is usually
caused by a disconnected trunk.
1. Check trunk wiring to ensure good connection; repeat test if wiring
correction made.
2. Locate another identical CO trunk and swap its wiring with one under
test. Repeat test on both trunks and determine if problem follows trunk
or remains at original port. If problem follows trunk, refer problem to
CO. If problem remains at port, replace circuit pack and repeat test.
1009
PASS
Detected tone was not pure dial tone. No action required.
PASS
Trunk was seized, and dial tone was detected. User-reported troubles on
this port should be investigated by using other port tests and by examining
trunk or external wiring.
Table 216.
TEST #0 Dial Tone Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...