DIOD-TRK (DIOD Trunk)
Issue 5 October 2002
1059
555-233-119
These errors cause the Dial Tone Test (#0) to run and are only considered
a problem if the Dial Tone Test fails (in which case Error Type 1537 also
shows up). In this case, the trunk may be put in "Ready-for-Service" state
(shown as "disconnected" by status command), which allows only
incoming calls. Run the Dial Tone Test (#0) and follow its outlined
procedures.
d. Single polarity ringing current - This error results from abnormal ringing
current, but does not prevent the incoming call from being accepted. This
error code is only logged as an informational event and causes no other
testing to occur.
e. Late CO Trunk release - This error indicates that the CO releases the trunk
at least four minutes after the PBX dropped the call. This error code is only
logged as an informational event and causes no other testing to occur.
NOTE:
At the administration terminal, busyout the affected port, and run a Long
test. If Dial Tone Test #0 passes, ignore this error. Release the port.
Table 215.
DIOD Trunk Errors with NO Tests
Error
Type
Aux
Data
Description and System Action
System Technician
Action
769
57392 CO not releasing after call is dropped from PBX end
(TN747B), or the loop is not open after a disconnect
(TN765). After several occurrences, an off-board
(TN747B) or on-board (TN465) warning alarm is
generated.
Refer problem to CO.
2561
57345 Single polarity ringing current. This error results from
abnormal ringing current, but does not prevent the
incoming call from being accepted. One cause could be
that the reverse current detector associated with the
port is failing. (Will not be detected by any tests.) The
other cause could be that normal current is not
detected. In this case, neither incoming nor outgoing
calls can be completed, and the dial tone test also fails.
Check for other errors.
2817
57393 CO released the trunk at least four minutes after the
PBX dropped the call. This error code is log only and
causes no other testing to occur. No alarm is generated.
Check for other errors.
3073
57376 No loop current on incoming call. The incoming
destination has already answered and no loop current
has been detected. If this is a hard fault, the dial tone
test and all outgoing calls should also fail.
Check for other errors.
3585
57424 No loop current on outgoing call. This error occurs on
attempt to seize a loop or ground-start trunk for an
outgoing call. An error occurs if loop current is not
detected or the caller hangs up before it is detected.
See Note at end of table.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...