Maintenance Commands
555-233-119
544
Issue 5 October 2002
test data-module
Use test data-module to run hardware diagnostic tests on a data module or data
channel. Test results are determined by the interface to the digital switch-data line
port, digital line port, or network control data channel.
!
WARNING:
Since the “clear long” options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test
data-module
extension
Extension of the data module or
data channel to be tested (per
dial-plan)
init
inads
craft
cust
nms
Test
sequence =
short
repeat = 1
none
short
Option for a brief series of
nondestructive diagnostic tests.
long
Option for a longer, more
comprehensive test series
(includes a destructive test)
repeat
number
How many times each test in the
sequence is repeated (1-100)
clear
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
schedule
Use the screen to schedule
execution of the command. The
command is placed in the
command queue and is executed
at the specified time. The
information displayed by the
command is sent to the system
printer instead of the screen.
2
2
See the Report Scheduler and System Printer feature specification for more details.
Examples:
test data-module 30000 l
test data-module 30000
test data-module 32000 sh r 2
test data-module 33000 l r 25
test data-module 33000 l r 25
schedule
test data-module 30000 c
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...