test customer-alarm
Use test customer-alarm to run hardware diagnostic tests on the leads of the
Processor and EPN maintenance circuit packs, used for customer-provided
alarms by closing the appropriate relay for 1 minute. Failure is verified by
checking the customer alarm attached to the specified circuit pack.
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test customer-
alarm
location
Extension of the data module or
data channel to be tested (per
dial-plan)
init
inads
craft
cabinet =1
carrier = a
repeat = 1
none
short
Runs test number 115
long
Runs test number 115 (same as
short test option)s
repeat
number
How many times each test in the
sequence is repeated (1-100)
clear
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
schedule
Use the screen to schedule
execution of the command. The
command is placed in the
command queue and is executed
at the specified time. The
information displayed by the
command is sent to the system
printer instead of the screen.
2
2
See the Report Scheduler and System Printer feature specification for more details.
Examples:
test customer-alarm
test customer-alarm schedule
test customer-alarm 02 r 2
test customer-alarm 01b r 25
test customer-alarm 01b r 25
schedule
test customer-alarm 2a
test customer-alarm 2a sh
test customer-alarm 01b l
schedule
test customer-alarm 3 c
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...