Maintenance Objects
1406
Issue 5 October 2002
The MMI circuit pack is maintained by the software like the Tone Detector circuit
pack, which can be removed and reinserted in any port board slot without
administration. Similarly, if a MMI circuit pack is removed from service logically by
failing the Archangel sanity scan test or is removed from service physically by
removing the circuit pack from the carrier, no error/alarm is raised against either
the MMI-BD or the MMI-PT maintenance objects. Therefore, if a MMI-LEV
error/alarm exists, yet no alarms have been raised against MMI-BD or MMI-PT
maintenance objects, a MMI circuit pack may have been removed from service
causing the MMI-LEV error/alarm. To resolve a MMI-LEV MAJOR alarm, restore
the number of MMI ports available for service to be equal to or greater than the
calculated port capacity.
To determine how many MMI circuit packs are needed for the MMCH feature:
1. Using the display system-parameters maintenance command, locate
the number listed in the
Minimum Maintenance Thresholds
(
MMIs
)
field and record this number.
2. Use the list configuration command to verify the number of MMI ports.
3. Compare this number with the value listed in the
MMI
field on the
System-Parameters Maintenance form (number listed in step 1 a minimum
thresholds number for MMI ports of between 0-128). Each MMI circuit pack
contains a maximum of 32 ports. If the number in the
MMIs
field is less than
or equal to 32, one MMI circuit pack is needed. If this number is 64, then
two MMI circuit pack are needed.
4. Use the list configuration command to verify that the number of MMI
circuit packs listed agrees with the required minimum port capacity (from
step 1). If the number of MMI circuit packs listed in the step 2 differs from
the calculated number, restore the number of MMI circuit packs to the
correct value, in order to resolve the MMI-LEV alarm.
Error Log Entries and Test to Clear Values
Table 368.
MMI-LEV Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/ Off
Board
Test to Clear Value
1
1
1.
The number of MMI resources in the system that are in service has fallen below the calculated
minimum value. If the number of in-service MMI ports falls below the MMCH port capacity (value
entered in the
Minimum Maintenance Thresholds for MMIs
field) on the
System-Parameters Maintenance form, a MMI-LEV error is logged. If this outage continues for 15
minutes, a MAJOR alarm is raised.
Any
None
MAJOR
OFF
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...