Maintenance Objects
1722
Issue 5 October 2002
j. Error Type 1538
The circuit pack was taken out of service because of an
excessive rate of uplink messages. Use test tone-clock PC long to reset
the circuit pack and put it back into service. If the command is not
successful, replace the circuit pack using the procedure described in the
preceding section,
‘‘How to Replace a Tone-Clock Circuit Pack’’
. If the
alarmed circuit pack is the active Tone-Clock of a duplicated pair, first
interchange Tone-Clocks via the set tone-clock PC command to avoid a
service outage. If the error occurs again within 15 minutes, follow normal
escalation procedures.
k. Error Type 2049 or 2305
These errors indicate the loss of one or more
clock signals from the reported Tone-Clock circuit pack, which was active
at the time of the error. The effect of any of these errors is described in the
table for error type 1. Diagnosis of the problem is the same for all four error
types, with the exception noted below.
1. Examine the Hardware Error Log for errors reported against circuit
packs in the same Port Network, especially TDM-CLK, TONE-BD,
DUPINT, SW-CTL, and EXP-INTF. Follow the repair or replacement
procedures indicated for any such errors found.
2. If the error is not corrected by resolving errors found in step 1, the
Tone-Clock circuit pack should be replaced. See the preceding
section,
‘‘How to Replace a Tone-Clock Circuit Pack’’
.
NOTE:
Replacing the circuit pack and retesting it with the test
tone-clock command is not adequate to retire this alarm and
return the Tone-Clock Circuit Pack to full service; the Clock
Health Inquiry test (#46) will continue to fail. Because the
ability to generate clocks was considered lost, once any
repairs have been made it is necessary to execute the set
tone-clock PC override command, forcing the circuit pack to
become active. If the problem has not actually been corrected,
this action may cause a disruption in service for active digital
facilities users.
3. If error 2305 or 3848 persists, all clock signals from the indicated
board were lost. If the reported Tone-Clock circuit pack is in a Port
Network with duplicated Tone-Clocks, the problem may lie with the
circuit pack responsible for selecting the active Tone-Clock circuit
pack (the t/c selector).
■
For a PPN, the t/c selector is the DUPINT circuit pack on
carrier A.
■
For an EPN, the t/c selector is the active EXP-INTF circuit
pack that is connected to the PPN. This is EXP-INTF 2A01 or
2B02 for EPN1 and 3A01 or 3B02 for EPN2.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...