ISDN-SGR (ISDN-PRI Signaling Group)
Issue 5 October 2002
1293
555-233-119
h. These error codes are used to report certain error messages received by
the ISDN-PRI Signaling Group for one of its associated B-channels. The
aux data field shows for which B-channel (port number) the message was
received.
The error code generated equals 3840+x, where x is a Cause Value
defined by the ISDN PRI Specification. Note that there is no Test to Clear
Value for these error types; selected ISDN cause values are placed in the
log when they are received, but no direct action or alarming is performed
solely in response to receiving them. They provide added data that may
prove useful when tracking down obscure networking and routing
problems.
Table 309
provides more information:
Table 309.
Descriptions of Error Codes 3842-3942
Error
Code
Description
Recommendation
3842
A request has been made
to use a transit network or
common carrier that cannot
be accessed.
1. From the circuit pack and port number (in the Aux
Data field), determine the trunk group against which
the error was reported.
2. Check all routing patterns containing this trunk group
for validity of interexchange carriers requested (IXC
field).
3843
No route to destination.
Request received to route
call through a transit
network that is recognized
but not allowed to carry the
call or not able to serve the
destination.
3846
The far-end switch has
indicated that the B-channel
(trunk) is not acceptable for
use in the call for which it
was requested.
This could indicate an administration problem (for
example, the local switch and the far-end switch have
different B-channels administered), or could reflect the
occurrence of a normal race condition (for example, the
local switch has requested use of a B-channel which the
far-end switch had just reserved for use on another call).
1. From the circuit pack and port number (in the
Aux
Data
field), determine the trunk group against which
the error was reported.
2. Issue the status trunk command for the indicated
trunk.
3. Refer to the “DS1 ISDN Trunk Service States” and
“ISDN-PRI Trunk Service States” sections of
ISDN-TRK for recovery suggestions.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...