ANNOUNCE (Announce)
Issue 5 October 2002
725
555-233-119
32003
Announcement port is in use.
1. Wait for all Announcement ports to become available.
2. Enter the save/restore announcements command.
32004
There are no announcements recorded on the Announcement Circuit Pack. The save
announcements command is not allowed to prevent the destroying of the
announcement file on tape [286 systems] or on the memory card [386 systems].
32005
Integrated announcement circuit pack is not present. The Announcement Circuit Pack is
not inserted, or it is defective.
1. Use list config to check for the presence of the circuit pack in the system.
2. If the Announcement Circuit Pack is present, use the test board PCSS command to
check the status of the Announcement Circuit Pack.
32006
Announcement Data Module not available.
1. Use the status command to check the status of the Announcement Data Module.
32007
Announcement Data Module out of service.
1. Use the status command to check the status of the Announcement Data Module.
32008
Announcement data is being saved or loaded.
1. Retry the command at 2-minute intervals a maximum of three times.
2. If the save/restore announcements command fails, escalate the problem.
32009
Required DATA-CHL is not administered or out of service. (A DATA-CHL is required to
save or restore announcements.)
1. Add a DATA-CHL if none is administered.
2. If a DATA-CHL is administered, use the status command to check the status of all
DATA-CHLs. At least one DATA-CHL should be in the in-service/idle state.
32010
32013
DATA-CHL is not administered, or it is unavailable. (A DATA-CHL is required to save or
restore announcements.)
1. Add a DATA-CHL if none is administered.
2. If a DATA-CHL is administered, use the status command to check the status of all
DATA-CHLs. At least one DATA-CHL should be in the in-service/idle state.
32012
Required Announcement Data Module is not administered.
1. Add an Announcement Data Module and repeat the command.
Table 67. Aux Data Error Codes and Recommended Repair Procedures —
Continued
Aux
Data
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...