UDS1-BD (UDS1 Interface Circuit Pack)
Issue 5 October 2002
1793
555-233-119
1320
FAIL
A CSU Module/Sync Splitter hardware failure, or an ICSU/Sync Splitter serial
interface audit failure was detected by the UDS1 circuit pack.
1. Replace the CSU module/Sync Splitter, and then run the test again.
2. If the test continues to fail with this error code, replace the UDS1-BD
circuit pack and run the test again.
3. If the test continues to fail with this error code, then the problem could be
in the I/O cable between the backplane and the CSU module/Sync
Splitter.
1321
FAIL
DTE LOS (loss of signal) was detected between the UDS1 board and the
CSU Module or the Sync Splitter. Either the UDS1 board, the CSU
Module/Sync Splitter, or the I/O cable between the backplane and the CSU
module/Sync Splitter (or any combination thereof) has failed. Attempt to
isolate the problem to one of these areas.
1. Replace the CSU Module/Sync Splitter and run the test again.
2. If the test continues to fail with this error code, then replace the
UDS1-BD board and run the test again.
3. If the test continues to fail with this error code, the problem could be in
the I/O cable between the backplane and the CSU module/Sync Splitter.
1322
FAIL
No 5 volts power detected from the UDS1 circuit pack to the CSU Module or
the Sync Splitter. Problem is probably due to an open fuse on the DS1 board
or a faulty ICSU/Sync Splitter.
NOTE:
Do not immediately swap DS1 boards as this may blow the fuse on the
new board.
1. If the test continues to fail with this error code, then replace the CSU
Module/Sync Splitter and run the test again.
2. Remove the UDS1 from the system and reinsert.
3. Run the test again once the board has finished its reset.
4. If the test continues to fail with this error code, then replace the
UDS1-BD board and run the test again.
5. If the test continues to fail with this error code, the problem could be in
the I/O cable between the backplane and the CSU module/Sync Splitter.
1323
FAIL
A service-affecting CSU Module/Sync Splitter audit failure was detected by
the UDS1 circuit pack. All administered ports on the UDS1 circuit pack are
affected and maintenance software will place the ports into the out-of-service
state.
1. Replace the CSU Module or the Sync Splitter.
Table 530.
TEST #138 Loss of Signal Alarm Inquiry Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...