
Maintenance Objects
1560
Issue 5 October 2002
Notes:
a. Error type - 1; with Aux Data of 40987 — could be caused by a noisy port
or link. This is an off-board problem detected by the port circuit. Check for
defective wiring, a defective voice terminal, or move the voice terminal
closer to the switch (in terms of feet of wire from the jack to the switch). If
the problem persists, replace the circuit pack. Once the problem has been
resolved, the alarm disappears after a predetermined amount of time.
Error Type - 1; with Aux Data of 1 to 20 — occurs when at least 15
off-board problems have been detected with the link to the terminal. When
an error with the link is detected, an on-board counter is incremented.
The user could experience a noisy port or link. This is an off-board problem
detected by the port circuit. Check for defective wiring, a defective voice
terminal, or move the voice terminal closer to the switch (in terms of feet of
wire from the jack to the switch). If the problem persists, replace the circuit
pack. Once the problem has been resolved, the alarm disappears after a
predetermined amount of time.
b. Error Type - 18 — is logged when the port in question is busied out by
maintenance personnel. Make sure the port is released from busyout by
the release port UUCSS pp/PCSSpp command.
c. Error Type - 257 — indicates problems transmitting to the voice terminal,
which can be caused by defective wiring. Defective wiring can cause
varying degrees of problems on different types of sets.
d. Error Type - 513 — is the result of an ID Request failure to respond to the
digital endpoint audit.
e. Error Type - 767 — an in-line event produces this error type when a
favorable response is received from running the Digital Line Electronic
Power Feed Test (#11). No craft action is necessary. This alarm will be
resolved with the passing of time.
f. Error Type - 769; with Aux Data 40963 — is the result of an unfavorable
response to the Electronic Power Feed/ Positive Temperature Coefficient
Test (#11).
Error Type - 769; with Aux Data 40988 — indicates that the EPF/PTC
circuit has been turned off due to an overcurrent condition.
Once the problem has been resolved, it may take up to one hour for the
alarm to clear due to the “leaky bucket” strategy. If the problem cannot be
resolved by one of the steps above, then replace the circuit pack.
g. Error Type - 1025 — is a problem with the voice terminal EEPROM. When
the voice terminal is repaired the alarm will be resolved with the passing of
time.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...