Maintenance Objects
1494
Issue 5 October 2002
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external printer
device. If the link has been disconnected already, this test just returns PASS. All
resources allocated for a PMS Printer Link are released after this test.
Table 400.
TEST #213 Link Tear Down Test
Error
Code
Test
Result
Description/ Recommendation
40
ABORT
Internal system error
50
ABORT
Internal system error
1. Retry the command at 1minute intervals a maximum of 5 times.
1010
ABORT
The link has been busied out to out-of-service.
1. Enter release journal wakeup-log|pms-log command to release the
link from busyout state.
2. Retry test journal wakeup-log|pms-log l command to execute the
test.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The link is torn down.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...