DID-TRK (DID Trunk)
Issue 5 October 2002
1001
555-233-119
Notes:
A common trouble on DID trunks, which reports no errors or alarms, occurs when
the CO busies out the port (disconnects port). This situation occurs when the CO
thinks there are problems with the DID port. In this case, no incoming calls are
possible through this port. In addition to complaints received from outside callers
trying unsuccessfully to call in, this problem can be diagnosed by listing
measurements on lightly used trunks. If a particular port is detected as not in use,
a call to the CO is necessary to get the connection back in service.
a. This condition occurs when the tone detector times out waiting for digits.
1 – Verify trunk administered wink/immediate-start parameter.
2 – Verify the dial type.
3 – Refer problem to the CO.
b. Rotary dial before wink – This condition occurs when the CO starts dialing
before the PBX sends wink on a wink-start trunk. 1 – Verify trunk
administered wink/immediate-start parameter.
2 – Refer problem to CO.
c. Rotary dial too early – This condition occurs when the CO starts dialing too
soon after seizure on an immediate-start trunk.
1 – Verify trunk administered wink/immediate-start parameter.
2 – Refer problem to CO.
d. Rotary dial pulse during wink – This condition occurs when the CO sends
rotary dial digits too soon after seizure on a wink-start trunk.
1 – Verify trunk administered wink/immediate-start parameter.
2 – Refer problem to CO.
e. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
f. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
g. Rotary dial pulse on-hook longer than 105 msec – Break between rotary
pulses is too long.
1 – Test trunk by performing an incoming test call.
2 – Refer problem to CO.
h. Rotary dial rate below eight pulses/sec – More than 135 msec between two
successive breaks.
1 – Verify trunk administered interdigit-timing parameters.
2 – Refer problem to CO.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...