Maintenance Objects
1768
Issue 5 October 2002
Notes:
a. Error Type 1 — indicates that the circuit pack has totally stopped
functioning or is not fully administered. The alarm is logged about 15
minutes after the circuit pack has been removed or 11-minutes after the
SAKI Test (#53) fails.
To be fully administered, a UDS1 circuit pack must meet all three of the
following conditions:
1. Have an entry in the circuit plan using the change circuit pack
command
2. Be administered using the add ds1 UUCSS command
3. Be physically inserted into the correct slot
3330(w)
46083
MIN/WRN
3
ON
3585 to
3601 (x)
Any
Misframe Alarm Inquiry
Test (#145)
MIN/WRN
3
OFF
test board UUCSS r 6
3840(y)
Any
None
3841(z)
4358
3842(aa)
46097
3843(ab)
46081
3900(ac)
Any
CPE Loopback Jack
Test (#1212)
3901(ad)
Any
Far CSU Loopback Test
(#1213)
3902(ae)
Any
One-Way Span Test
(#1214)
3999(af)
Any
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the
circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered
on the circuit pack.
3.
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
4.
Major alarms on this MO may be downgraded to minor or warning alarms based on values set in
the set options command.
Table 524.
DS1 Interface Circuit Pack Maintenance Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...