ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 5 October 2002
665
555-233-119
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and
translations (such as station type, dial type, network connection) with information
kept in the software. The software is updated with the switchhook state reported
by the port processor. When the ringer is in the off state, this test also turns off the
station’s ringer to prevent constant ringing caused by defective hardware.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list config,
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between
the internal ID and the port. If this is not the case, dispatch to check to
ensure that there is a valid board inserted.
Table 47. TEST #36 Station Status and Translation Audits and Updates Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1004
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use display port PCSSpp to determine the station
extension. Use status station to determine the service state of the port. If
the service state indicates that the port is in use, the port is unavailable for
certain tests. (Refer to the “Status Commands” section in Chapter 8,
“Maintenance Commands and Trouble-Clearing Aids”, for a full description
of all possible states.) Wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 46. TEST #35 Battery Feed Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...