DATA-CON (Network Control Driver)
Issue 5 October 2002
975
555-233-119
DATA-CON (Network Control Driver)
The TN2402/TN798 Processor circuit pack contains the following objects: the
SW-CTL (Switch Control), four DATA-CHLs (Data Channels), the DATA-CON
(Network Control Driver), and the generic hardware that interfaces with the TDM
Bus (DATA-BD). The DATA-CON (Network Control Driver) is the subject of this
section. The DATA-CHLs (Network Control Channels) are also described.
Together the 4 DATA-CHLs and the DATA-CON provide a data communications
interface that allows DTE equipment connected to port circuit packs to
communicate with software applications running on the system. The DATA-CON
represents the interface to the control channel of the TDM Bus. Each DATA-CHL
represents a dial-up/dial-out asynchronous communication port that interfaces to
the TDM Bus. The DATA-CON supports the signaling required to establish and
tear down a connection between the terminal equipment and a software
application. Data is transported between the terminal equipment and the software
over the connection established over the DATA-CHL.
From an external (user) point of view, the DATA-CON is not directly accessible via
a system technician command; that is, there is no object command word that
represents it. Instead, the DATA-CON is tested under the guise of the DATA-CHLs
that it controls. The test data-module <ext> [short | long] command tests the
DATA-CON along with the DATA-CHL designated by <ext> but all Test Results are
associated with the DATA-CHL Maintenance Name.
From an internal (system software) point of view, the DATA-CON uses the same
set of tests as the DATA-CHLs. Therefore, the DATA-CON assumes the same
Error Type and Aux Data values as the DATA-CHLs in the Hardware Error Log. It
is also alarmed at the same Alarm Level (that is, MINOR, ON BOARD) in the
Alarm Log. In both logs, the Maintenance Name is DATA-CON.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
DATA-CON
MINOR
none
Network Control Driver
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...