S-SYN-PT (Speech Synthesis Port)
Issue 5 October 2002
1583
555-233-119
Speech Synthesis DSP Tone Test (#165)
The digital signal processor (DSP) associated with each port can generate a
440-Hz tone whose presence can be detected by TN748 General Purpose Tone
Detector circuit packs. A 440-Hz tone is generated for 500 msec on a specified
time slot which is being listened to by the detector circuit. If the detector
determines the tone is present on the time slot, the test passes; otherwise, it fails.
Table 450.
TEST #165 Speech Synthesis DSP Tone Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. You must wait
until the port is idle (yellow LED if off) before retesting.
1. If the port is idle retry command at 1-minute intervals a maximum of 5
times.
1001
1002
1003
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1021
ABORT
The 440-Hz tone was not detected by the Tone Detector circuit and inter-digit
time-out has occurred on the Tone Detector circuit.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, verify all Tone Detector circuit packs in the
system are functioning correctly by checking the Error Log and using the
test board PCSS long command. Replace any faulty Tone Detector circuit
packs and repeat the test.
3. If the test continues to abort, replace the Speech Synthesis circuit pack.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
The 440-Hz tone was not detected by the Tone Detector circuits.
1. If the test fails again, verify all Tone Detector circuit packs in the system are
functioning correctly by checking the Error Log and using the test board
PCSS long command. Replace any faulty Tone Detector circuit packs and
repeat the test.
2. If the test fails again, replace the Speech Synthesis circuit pack.
PASS
The 440-Hz tone has been detected correctly. User-reported troubles should be
investigated using other tests and verifying other ports on this circuit pack are
working correctly.
Continued next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...