DATA-CHL (Data Channel)
Issue 5 October 2002
967
555-233-119
1000
ABORT
For this test, an Error Code of 1000 can have one of several different
meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. System resources required to run this test are not available.
c. Internal system error
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Journal Printer Link, PMS Link, or secondary
administration terminal connection) as described previously in the
‘‘Status of
Data Channels’’
section. If so, check for errors on the function that is using
the DATA-CHL. If there are no errors, there is a high probability that the
DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely test
the target DATA-CHL:
1. If the target DATA-CHL is in use for some other function, busyout the
function (PRI-CDR/SEC-CDR, SYS-PRNT, PMS-PRNT/JNL-PRNT,
PMS-LINK) or the DATA-CHL (secondary administration terminal
connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Restore any busied out PRI-CDR/SEC-CDR, SYS-PRNT,
PMS-PRNT/JNL-PRNT, PMS-LINK MOs to service before moving on to
another activity.
1002
ABORT
For this test, an Error Code of 1002 can have one of two different meanings:
1. System resources required to run this test are not available.
2. Internal system error
1006
ABORT
System resources required to run this test are not available.
1016
ABORT
Resources for the test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018
ABORT
Test disabled via software patch.
2000
ABORT
Resources for the test are not available.
2003
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 176.
TEST #110 Data Channel Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...