Maintenance Objects
1462
Issue 5 October 2002
PKT-INT (Packet Interface)
The Packet Interface (PKT-INT) interfaces between the TN2402/TN798 Processor
circuit pack and packet endpoints (such as ISDN-BRI stations or ISDN-PRI
trunks). Two instances of PKT-INT are provided on the TN2402/TN798 Processor
circuit pack:
■
PKT-INT 1 (1A1) communicates through the TDM bus only. It provides
signaling for circuit packs that can receive signaling packets over the TDM
bus, e.g., the TN767E DS1 Interface circuit pack (for ISDN-PRI
applications) and the TN556C circuit pack (for ISDN-BRI applications).
■
PKT-INT 2 (1A2) communicates through the Packet bus only. It provides
signaling only for circuit packs that can receive their signaling packets over
the Packet Bus, e.g., the TN464F UDS1 circuit pack and the TN556B
circuit pack
The TN2402/TN798 Processor circuit pack is not equipped with a direct interface
to the Packet Bus. In order to use the Packet Bus, PKT-INT 2 (1A2) connects via
the Processor circuit pack’s TDM Bus interface to a special Bus Bridge module on
the TN799 C-LAN circuit pack. That module provides a Packet Bus interface on
one side and a TDM Bus interface on the other, and PKT-INT 2 is therefore able to
access the Packet Bus through it.
PKT-INT 2 is enabled only when the following conditions are met:
■
The system contains at least one TN799 C-LAN circuit pack, and
■
The Packet Intf2? field on the Maintenance-Related System Parameters
form is set to “y”.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
S is the instance of the Packet Interface on the TN2402/TN798 Processor circuit pack
(1 or 2).
Full Name of MO
PKT-INT
MAJOR
reset packet-interface 1AS
Packet Interface
PKT-INT
MINOR
test packet-interface 1AS
Packet Interface
PKT-INT
WARNING
test packet-interface 1AS
Packet Interface
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...