Maintenance for CSI systems
555-233-119
94
Issue 5 October 2002
NOTE:
Before placing an outgoing ISDN-PRI test call, verify that the FAC on the
System Features screen has been administered, and the Far End Test Line
No and TestCall Bearer Capability Class (BCC) fields are administered on
the Trunk Group Administration screen. If the ISDN-PRI trunk service type is
“cbc” (call by call), then the
Testcall Service
field on Trunk Group
Administration screen be administered.
To initiate an outgoing ISDN-PRI test call in the asynchronous method, type:
test isdn-testcall <grp>/<mbr> [minutes]
This command enables you to specify a specific the trunk on which to originate
the ISDN-PRI test call.
NOTE:
The optional qualifier can also be used that specifies in minutes the duration
of the test call. If no duration is specified, the default duration is used which
is 8.4 or 9.6 seconds. The qualifier “minutes” accepts the numeric values
one through 120 (that is, two hours = 120 minutes).
Screen 17
shows a typical response to the test isdn-testcall command:
Screen 17.
Typical Response to Test ISDN-Testcall Command
test isdn-testcall
Port Maintenance Name Test Number Test Result Error Code
1B1501 ISDN-TRK 258 PASS
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...