Maintenance Objects
555-233-119
670
Issue 5 October 2002
1005
ABORT
The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13, 14 and 15
— TN769 vintages 3, 4 and 5
1018
ABORT
Test has been disabled via administration. The default for the
Test
field on
the Station screen is y. Determine why this field has been set to
n
for this
station. It may be due to application Test #48, which can disturb users or
terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Test
field to y.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service
state failed or the attempt to put the port in connection with a tone source
failed (this could be a tone-clock problem). The tone-clock and tone
detectors could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7
FAIL
The conference test or the noise test failed. This could cause noisy or
unreliable connections, or users calling this port may hear an echo. The
problem can also be off-board, as described below.
13
The reflective loop around with gain set to low and the 600-ohm balance
failed. This will cause noisy or unreliable connections.
14
The reflective loop around test (with the gain set to high, using RC balance)
failed. This could cause noisy or unreliable connections. The problem can
also be off-board, as described below.
15
The nonreflective loop around test failed. This could cause noisy or
unreliable connections, or users calling this port may hear an echo. The
problem can also be off-board, as described below.
More information follows.
Table 48. TEST #47 Loop Around and Conference Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...