BRI-SET, ASAI-ADJ, BRI-DAT
Issue 5 October 2002
819
555-233-119
BRI-SET, ASAI-ADJ, BRI-DAT
The TN2208 ESAI MFB provides the Avaya Definity Server CSI with an Ethernet
interface to Adjunct-Switch Application Interface (ASAI) and adjuncts (for
example, CONVERSANT
®
Voice System). This circuit pack contains 8 ports of
line circuit interface, each of which operates with two B-channels (referred to as
B1 and B2 throughout this section) and one D-channel as specified in the
ISDN-BRI Specification. In this context, the term ‘ ‘ ISDN-BRI port’’ is used to refer
collectively to ports on the TN2208 MFB circuit pack which is connected to ASAI
or adjuncts. The TN2208 ESAI MFB is handled by switch software as it is an ISDN
BRI compatible board and all maintenance actions referring to ASAI and Adjunct
Links in this section apply.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
Where P is the port network number (1 for PPN); C is the carrier designation (A, B, or C); SS is
the address of the slot in the carrier where the circuit pack is located (01, 02, etc.); and pp is the
2-digit port number (for example, 01). The alternate name field contains the extension of the
endpoint. This field is used to distinguish between endpoints on the same port.
Full Name of MO
BRI-SET
WARNING
2
2.
The alarm level for ASAI and adjuncts may be administered using the set options command. The
alarm level can be set independently for Off-Board and On-Board alarms to WARNING, MINOR,
or MAJOR for all ASAI and adjuncts in the system.
test station extension l,
test data-module extension
ISDN-BRI Set
ASAI-ADJ
MAJOR
2
test station extension
ASAI-Adjunct
ASAI-ADJ
MAJOR
2
test data-module extension
ASAI-Adjunct
ASAI-ADJ
WARNING
3
3.
Alarming for an ASAI and adjuncts is disabled if the adjunct asks the switch to suspend
maintenance. When this occurs, an error and a WARNING alarm are logged against the endpoint.
Busying out and releasing the ASAI station or ADJLK station will clear the alarm.
test data-module extension
ASAI-Adjunct
ATT-ADJ
MAJOR
2
test station extension
-Adjunct
ATT-ADJ
MAJOR
2
test station extension
-Adjunct
ATT-ADJ
WARNING
3
test station extension
-Adjunct
LGATE-AJ
MAJOR
2
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
MAJOR
2
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
WARNING
3
test station extension
Ethernet ASAI-Adjunct
ATTE-AJ
MAJOR
2
test station extension
Ethernet -Adjunct
ATTE-AJ
MAJOR
2
test station extension
Ethernet -Adjunct
ATTE-AJ
WARNING
3
test station extension
Ethernet -Adjunct
BRI-DAT
test data-module
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...