Maintenance Objects
555-233-119
846
Issue 5 October 2002
CABINET (Cabinet Sensors)
The Compact Modular Cabinet (CMC) AC Power Supply (650A) supports one
alarm lead that indicates the state of both the power and fan. With multiple
cabinets, alarm leads from each cabinet are tied into a single lead. The CMC uses
variable speed fans to reduce noise. The CMC power unit contains Thermal
Speed Control and an alarm circuit. A variable speed fan has a 3-pin connector for
the variable input power for speed control and its alarm circuitry.
See the next table for the LED and alarm conditions.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to
Run
1
1.
Where P is an appropriate port network number determined in the Port field from the
Alarm or Error Log.
Full Name of MO
CABINET
MAJOR
test environment P
Cabinet Sensors
Condition
LED Status
Alarm State
Fan Alarm
Normal
Red off;
Yellow on
Open
Normal
No input power
Red off;
Yellow off
Closed
No input power
DC output not present
(except Neon)
Red on;
Yellow off
Closed
DC output not present (except Neon)
Fan alarm
Red on;
Yellow on
Closed
Fan alarm
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...