CO-DS1 (DS1 CO Trunk)
Issue 5 October 2002
905
555-233-119
Table 156.
TEST #7 Conference Circuit Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
The test was aborted. System resources required to run this test were not
available. The port may be busy with a valid call. Use display port
PCSSpp to determine the trunk group/member number of the port. Use
status trunk to determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for certain tests. Wait
until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1002
ABORT
The test was aborted. The system could not allocate time slots for the test.
The system may be under heavy traffic conditions, or it may have time slots
out of service due to TDM-BUS errors. Refer to the TDM-BUS (TDM bus)
maintenance documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic
and the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some of the tone
detectors may be out of service. Issue list measurements tone-receiver
to display basic information about the system’s tone receivers.
1. Look for TTR-LEV errors in the error log. If present, refer to the
TTR-LEV maintenance documentation.
2. Look for TONE-PT errors in the error log. If present, refer to the
TONE-PT maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals for a
maximum of 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use the status station
or status trunk command to determine when the port is available for
testing.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, and the port is not in use, escalate the
problem.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...