DATA-BD (Data Channel Processor Circuit Pack)
Issue 5 October 2002
945
555-233-119
DATA-BD (Data Channel Processor
Circuit Pack)
The DATA-BD is a generic hardware that supports the Data Channels on the
Processor circuit pack. All circuit packs that have an interface with the TDM Bus
have a common set of generic hardware that provides the TDM Bus interface.
Consequently, these circuit packs share a common set of tests that verify the
integrity of the generic hardware. The circuit packs and common set of tests that
they share are described in XXX-BD (Common Port Circuit Pack) Maintenance
documentation. Because the Processor circuit pack has this common set of
hardware, it is classified in the XXX-BD Maintenance documentation as a service
port circuit pack.
The DATA-BD MO is different from other XXX-BD MO in that the DATA-BD MO is
always inserted (because it is part of the Processor circuit pack). Also because
the DATA-BD MO is part of the Processor circuit pack, some board commands do
not apply to this MO. To access the DATA-BD MO, use the test network-control
[short | long] command.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
DATA-BD
WARNING
test network-control
Network Control Circuit Pack
DATA-BD
MINOR
test network-control
Network Control Circuit Pack
DATA-BD
WARNING
test network-control
Network Control Circuit Pack
Table 168.
Data Channel Processor Circuit Pack Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test data-module <ext> sh
r 1
1(a)
0
Data Channel Reset
Test (#107)
MINOR
ON
test data-module <ext> l
23 (b)
0
None
WNG
OFF
257
Any
Control Channel Test
(#52)
MINOR
ON
test network-control [a | b]
sh r 20
257 (c)
0
None
513 (d)
Any
None
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...