Maintenance Objects
1842
Issue 5 October 2002
3
FAIL
The Far CSU Loopback Test was not set up properly. The framed 3-in-24 test
pattern, generated by the UDS1 Interface circuit pack and looped back
through the far-end CSU, could not be detected properly by the UDS1 circuit
pack.
1. Retry the test ds1-loop UUCSS far-csu-loopback-test-begin
command.
2. If the Far CSU Loopback test continues to fail with this error code, the
problem could be with the UDS1-BD board, the far-end CSU equipment,
or somewhere in between. Run the test ds1-loop UUCSS
cpe-loopback-jack-test-begin command to see if the CPE Loopback
Jack test which is closer to the UDS1-BD board is successful. (If a CPE
Loopback Jack device is not being used, then run the test ds1-loop
UUCSS ds1/csu-loopback-tests command to see if these even closer
loopback tests succeed). If the closer loopback test fails, follow the
maintenance strategy associated with that loopback.
PASS
The Far CSU Loopback test has successfully began executing. The test will
continue to run until the system technician enters the test ds1-loop UUCSS
end-loopback/span-test command or the release board UUCSS command.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 543.
TEST #1213 Far CSU Loopback Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...