Maintenance Objects
1730
Issue 5 October 2002
Notes:
a. A failure in the tone generation facility on the indicated circuit pack has
been detected. Replace the circuit pack. See
‘‘How to Replace a
Tone-Clock Circuit Pack’’
in the TONE-BD section.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. The tone generation facility is having problems verifying that tones have
been connected as requested.
d. The tone generation facility may or may not be able to generate tones.
e. Infrequent errors, at a rate which does not bring up an alarm, probably do
not affect service, unless there are customer complaints of no tones, or
incorrect tones which can not be explained in any other way. However, if an
alarm is raised because this error is being repeatedly logged, then the
circuit pack should be replaced. See
‘‘How to Replace a Tone-Clock Circuit
Pack’’
in the TONE-BD section.
513(d,e)
17666
Tone Generator
Audit/ Update Test
(#41)
MINOR
ON
test tone-clock PC r 3
769
Any
Transmission Test
(#40)
MAJOR/
MINOR
ON
test tone-clock PC r 3
1025
Crosstalk Test
(#90)
MAJOR/
MINOR
ON
test tone-clock PC l r 2
1281
Any
Tone Generator
Audit/ Update Test
(#41)
MINOR
ON
test tone-clock PC r 3
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 512.
Tone Generator Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...