ISDN-TRK (DS1 ISDN Trunk)
Issue 5 October 2002
1325
555-233-119
Figure 38.
ISDN-PRI Outgoing Test Call
Synchronous Commands
You can demand a synchronous outgoing test call by using the following
maintenance commands:
■
test trunk trunk-group-no/member-no long [repeat number]
■
test board board-location long [repeat number]
■
test port port-location long [repeat number]
Whenever a circuit translates to an ISDN-PRI trunk during a Long Test Sequence,
an outgoing test call is invoked. If the B-channel is unrestricted (B8ZS or HDB3)
the default duration of the test call is 8.6 seconds. Otherwise, if the B-channel is
restricted (ZCS) the default duration of the test call is 9.4 seconds. Once the test
call completes, the bit error rate is retrieved from the Maintenance/Test Digital
Port. A bit error rate greater than zero is reported as a failure to the Manager I
terminal (MGRI). A failure indicates the need to run further diagnostics, such as
the test isdn-testcall command.
If no Maintenance/Test circuit pack exists, the outgoing ISDN-PRI test call is
established over a high speed data channel on the Network Control (NETCON)
circuit pack (DATA-BD).
PI (TN765)
or
PACCON
(TN778)
NETCON SPE
D-channel Setup
B-channel
B-channel
TDM BUS
M/T
TN7771B
DS1/UDS1
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...