Maintenance Objects
1460
Issue 5 October 2002
2059
ABORT
The Maintenance/Test Packet Bus port has reported a hardware failure.
1. Re-enter the test command.
2077
ABORT
The Maintenance/Test Circuit Pack Query located more than one
Maintenance/Test Packet Bus port in the system.
NOTE:
The software should not allow this to occur. This is an Internal system
error. Attempt the following work-around steps.
1. Remove all Maintenance/Test circuit packs from the system.
2. Insert one Maintenance/Test circuit pack (there should not be more than
one in a system).
3. Re-enter the test command.
2100
ABORT
Maintenance could not allocate all of the necessary system resources to
perform this test.
2500
ABORT
An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
XYZZ
FAIL
The Maintenance/Test Packet Bus port has detected faults on the Packet Bus.
The error code is encoded as follows:
1xxx
The Maintenance/Test Packet Bus port has reconfigured the Packet Bus
around the faulty leads. This action occurs only in high or critical reliability
systems, and such a failure code should not appear in an R9CSI system.
2xxx
The Maintenance/Test Packet Bus port is unable to correct all of the Packet
Bus faults it has detected.This action occurs only in high or critical reliability
systems, and such a failure code should not appear in an R9CSI system.
x0xx
None of the Packet Bus faults are open faults.
x1xx
At least some of the Packet Bus faults are open faults. Look for Error Type
2305 in the Error Log. The Aux Data value indicates the number of open leads.
xxZZ
The last 2 digits of the error code indicate the total number of faulty Packet
Bus leads detected by the Maintenance/Test Packet Bus port.
1. Refer to the "Packet Bus Fault Isolation Flowchart" section in Chapter 9 to
determine the cause of the failures.
PASS
No faults have been detected on the Packet Bus by the Maintenance/Test
circuit pack. This indicates that the Packet Bus is operating correctly.
Table 388.
TEST #572 Maintenance/Test Circuit Pack Query Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...