status audits
Issue 5 October 2002
419
555-233-119
status audits
Use status audits to display Data Relation Audits that are built into the switch.
Data Relation Audits check for inconsistencies between selected data items in the
switch, and report inconsistencies. Data Relation Audits are useful during
development and testing phases of projects to uncover software errors. In the field
they help the switch to recover from data corruption before service is interrupted.
This command displays the date and time that the requested interval begins, the
number of times that the full sequence of audits executes (audit cycles), and
status information about each audit that detected a problem or aborted during the
interval. The status information contains:
■
The name of the audit
■
The number of times that an audit ran and corrected an error
■
The number of times that an audit ran and detected an irreparable error
■
The number of times that an audit ran and aborted
■
The date and time that the audit first detected a problem (only for
cumulative)
■
The time of the most recent error detected by the audit (only for
cumulative)
Audit data information cumulates from the last reboot or the last clear audits
cumulative command, and for peak hours since the last reboot or the last clear
audits peak-hour or clear audits cumulative commands.
NOTE:
Single process restarts, warm starts, cold 2 restarts, cold 1 restarts, or
processor interchanges do not clear this data.
Audits can execute directly using test MO. For example, test MO l 8192 p 512 t 0
executes the Station Connections Audits, audit lnames and numbers (pnames)
included in the Table Of Audits. When the “test MO” command executes an audit,
report results appear on the screen. In general, errors discovered from a demand
tests are not logged in the error logs. To be consistent with other error logging,
and to avoid confusion, errors that are discovered from a demand test that
executes an audit are not displayed.
The screen does not automatically update, but reflects the system at the time of
the request.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...