BRI-SET, ASAI-ADJ, BRI-DAT
Issue 5 October 2002
825
555-233-119
f. This error occurs when the signaling link associated with a BRI endpoint
has too much link establishment related traffic. This could occur if the
signaling link is bouncing between assigned and established states.
Software will suspend activity to this endpoint for 75 minutes when the
endpoint is alarmed due to this problem (note that service suspension does
not occur if the endpoint is an ASAI or adjunct). If this problem persists,
replace the endpoint. If replacing the endpoint does not fix the problem,
follow normal escalation procedures.
g. This error occurs when the ASAI-ADJ or ATT-ADJ or LGATE-AJ or
ATTE-AJ message is not transmitted because the PKT-CTRL (Packet
Control Circuit Pack) transmit buffers are exhausted. Frequent or
persistent occurrence of these events may indicate a hardware problem or
traffic overload on the PKT-CTRL, the signaling link, or the ASAI or adjunct.
Attempt to resolve the problem by following the repair procedures for the
PKT-CTRL. If these attempts fail, the problem should be escalated
because re-engineering of the traffic on the PKT-CTRL, signaling link, or
adjunct may be necessary.
h. This error occurs when the ASAI message is not transmitted because the
transmit buffer for the ASAI link is full, causing the link to be flow controlled.
Frequent or persistent occurrence of these events may indicate a hardware
problem or traffic overload on the PKT-CTRL, the signaling link, or the
ASAI or adjunct. Attempt to resolve the problem by following the repair
procedures issued by the manufacturer of the adjunct. If these attempts
fail, the problem should be escalated because re-engineering of the traffic
on the PKT-CTRL, signaling link, or adjunct may be necessary.
i. This error indicates a problem with Layer 2 over the D-channel between the
switch and the endpoint. When this error occurs, an alarm is raised against
the station or adjunct. Use test station
<extension
> short and look at the
results of the BRI XID Test (#628). If this test fails, follow the repair
procedure for Test #628.
j. This error indicates a problem with the B-channel connection between the
switch and the endpoint. When this error occurs, a warning alarm is raised
against the endpoint. Use test station <
extension>
long and look at the
results of the BRI Remote Loop Back Test (#627). If this test fails, follow the
repair procedure for Test #627.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...