Maintenance Objects
555-233-119
900
Issue 5 October 2002
Notes:
a. Error Type 1—Aux Data 57408—No tip ground is detected on an outgoing
call.
Aux Data 57487—PBX could not get “loop close” signal (TN767).
The DS1 Interface circuit pack detected a hardware fault. These errors
cause the Dial Tone Test (#314) to run and are only considered a problem if
the Dial Tone Test fails (in which case Error Type 1025 also shows up). In
this case, the trunk may be put in ready-for-service state (shown as
"disconnected" by status command), which allows only incoming calls. Run
the Dial Tone Test (#314) and follow its outlined procedures.
b. Error Type 15—This is a software audit error that does not indicate any
hardware malfunction. Run Short Test Sequence and investigate
associated errors (if any).
c. Error Type 18—System Technician has busied-out the trunk to the
out-of-service state. No calls can be made on this trunk except the Facility
Access Test Call.
d. Error Type 130—This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type: 57392—no external
release on PBX disconnect [E030]. Escalate the problem.
f. Error Type 513—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type: 57393—belated
external release on PBX disconnect [E031]. Escalate the problem.
g. Error Type 769—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type:—57484, fault is
detected on tip/ring [E08C]. Escalate the error.
h. Error Type 1793—DS1 Interface circuit pack is out-of-service. Look for
DS1-BD errors in the Hardware Error Log. Refer to the DS1-BD (DS1
Trunk Circuit Pack) Maintenance documentation for details.
i. Error Type 2562—Retry Failure error. This error is logged only. It is not a
hardware failure and hence does not start any testing or generate any
alarms. This error comes from call processing and is generated when a
second attempt (retry) to seize an outgoing trunk fails.
j. Error Type 2817—Glare error. This error is logged only. It is not a hardware
failure and hence does not start any testing or generate any alarms. This
error is the result of a simultaneous seizure of a two-way trunk from both
the near-end and the far-end. Attempt to place the call again. If the error
persists, execute the Dial Tone Seizure Test (#314) and follow those
procedures.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...