555-233-119
960
Issue 5 October 2002
30
31
32
33
40
41
70
75
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
For this test, an Error Code of 1000 can have one of several different
meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. No other DATA-CHLs are administered and, therefore, not available to
place the call to the target DATA-CHL.
c. All other DATA-CHLs are busy and, therefore, not available to place
the call to the target DATA-CHL.
d. System resources required to run this test are not available.
e. Internal system error
Note the results of Tests #110 and #111 in the Short Test Sequence for the
target DATA-CHL. If the results of Tests #110 and #111 are both PASS, then
there is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely test
the target DATA-CHL:
1. Determine if the target DATA-CHL is in use for some other function (that
is, CDR Link, System Printer Link, Journal Printer Link, PMS Link, or
secondary administration terminal connection) as described previously in
the "Status of network Control Data Channels" section. If so, check for
errors on the function that is using the DATA-CHL. If there are no errors,
there is a high probability that the DATA-CHL is not defective. Proceed
with the remaining steps only if it is necessary to completely test the
target DATA-CHL.
2. If the target DATA-CHL is in use for some other function, busyout the
function (CDR Link, System Printer Link, Journal Printer Link, PMS Link)
or the DATA-CHL (secondary administration terminal connection only).
Table 175.
TEST #109 Data Channel Remote Maintenance Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...