Maintenance Objects
555-233-119
664
Issue 5 October 2002
1018
ABORT
Test has been disabled via administration. The default for the
Test
field on
the Station screen is y. Determine why this field has been set to
n
for this
station. It may be due to application Test #48, which can disturb users or
terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Test
field to y.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service
state failed or the attempt to put the port in connection with a tone source
failed (this could be a tone-clock problem). The tone-clock and tone
detectors could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The port’s battery feed chip is unable to supply sufficient power to the
terminal equipment. This may occur when the test is performed at the same
time that the terminal equipment goes off-hook.
1. Use status station to determine when the port is available for testing.
When the port becomes available for testing, retry the command at
1-minute intervals a minimum of 5 times.
2. If the test continues to fail, determine whether the customer is
experiencing problems on this line. Replace the circuit pack only if the
customer is experiencing problems.
PASS
The port’s battery feed chip is able to provide power to the station
equipment to detect on-/off-hook. However, the battery feed chip may still
be unable to provide power for touch-tones. If tones are heard when buttons
are pressed, the battery feed chip is functioning correctly. Otherwise,
replace the circuit pack because this port is defective. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, by examining the station, and by ensuring that the
terminal is correctly translated as off-premises or on-premises.
NOTE:
This test always passes for TN742 Analog circuit packs prior to
Vintage 6.
Table 46. TEST #35 Battery Feed Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...