Maintenance Objects
1360
Issue 5 October 2002
g. Error Type 513: transient hardware problem.
Aux Data:
1. If the same Error Type/Aux Data value occurs more than once in a
24 hour period, the circuit pack should be replaced. See
‘‘Shutting
down NT on the TN802’’
before removing the circuit pack.
If the MAPD board detects only one of these hardware problems, then the
error is resolved when none of these faults are detected for 10 minutes.
h. Error Type 514: LAN External RAM Error; hardware fault in the PPE
external RAM, used for message buffering to and from the Packet Bus.
This error should not occur regularly.
1. If this error occurs 10 times within 30 minutes, replace the circuit
pack. See
‘‘Shutting down NT on the TN802’’
before removing the
circuit pack.
i. Error Type 769: Transmit FIFO Underflow (threshold is 3 errors within 10
minutes); the circuit pack cannot find the “end of frame” bit when
transmitting a frame to Packet Bus.
1. Clear the alarm using the following command sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS long clear
d. release board UUCSS
2. If the error recurs within 10 minutes, replace the circuit pack. See
‘‘Shutting down NT on the TN802’’
before removing the circuit pack.
j. Error Type 770: unable to Write LAN Translation RAM (threshold is 2 errors
within 10 minutes); a call is aborted because there are no available
translation RAM locations for the call connection attempt.
1. Clear the alarm using the following command sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS long clear
d. release board UUCSS
2. If the error recurs within 10 minutes, replace the circuit pack. See
‘‘Shutting down NT on the TN802’’
before removing the circuit pack.
4352
External RAM failure
4353
Internal RAM failure
4355
Internal ROM failure
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...