555-233-119
1224
Issue 5 October 2002
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. Error Type 1 — represents a failure of the CLAN hardware carrying the
signaling group D-Channel. Check for errors against the CLAN-BD
maintenance object.
b. Error Type 257 — tracks failures of the H.323 signaling-group PING test.
H.323 signaling-group PING test failures are documented later in this
maintenance object.
c. Error Type 513 — tracks excessive round trip delay of the H.323
signaling-group PING test (if the round-trip delay exceeds 4 seconds).
d. Error Type: 770 — tracks excessive latency and packet-loss from
background IP measurements collected by the Media Processor Board.
e. Error Type 1025 — indicates that the signaling group has been placed into
a BYPASS condition because of IP network congestion. The signaling
group accepts incoming calls, but all outgoing calls are denied. The system
routes these calls over a secondary route, if one has been administered.
f. Error Type 1281 — implies that no medpro resources are in-service to
provide media connections for the trunk members of the signaling group.
g. Error Type 1794 — The Sig Group reported that the far-end has detected
excessive packet latency or loss.
h. Error Type 2049 — A Keep-Alive timer is set for every registered endpoint
on the Remote Office, and the switch expects Keep-Alive update within
that timer’s time period. If the update does not occur, a message is
generated that causes an error to be logged against MO REM-OFF, as well
as MO H323-SGRP. Because the signaling group is still known, the error
against MO H323-SGRP generates a Minor alarm. This error is only valid if
the change signaling group form has the
RRQ
field set to
y
. This error
counter is only set if a failure has been detected by Call Processing and it
notifies maintenance software. The Keep-Alive Error Type 2049 clears only
after a registration occurs and Error Type 2305 clears.
2049(h)
Keep Alive Failure
MINOR
OFF
test sig-group grp#
2305(i)
Gateway Unregistered
MINOR
OFF
test sig-group grp#
Table 278.
H323-SGRP Signaling Group Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...