ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 5 October 2002
669
555-233-119
Table 48. TEST #47 Loop Around and Conference Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7
ABORT
The port was seized by a user for a valid call.
1. Use display port PCSSpp to determine the station’s extension. Use
status station extension to determine the service state of the port. If
the port is in use, it is unavailable for certain tests. Wait until the port is
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test were not available. The port may
be busy with a valid call. (This could be a Music-on-Hold port.)
1. Use display port PCSSpp to determine the station’s extension. Use
status station extension to determine the service state of the port. If
the port is in use, it will be unavailable for certain tests. Wait until the
port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to "TDM-BUS (TDM Bus)" Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to "TTR-LEV
(TTR Level)" Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to "TONE-PT
(Tone Generator)" Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
1004
ABORT
The port has been seized for a valid call during the conference or noise test.
Use status station to determine when the port is available for testing.
1. If the circuit pack is a TN742 with vintage 10 or less, this test is not
valid. Otherwise, go to Step 2.
2. When the port is available for testing, retry the command at 1-minute
intervals a maximum of 5 times.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...