Maintenance Commands
555-233-119
342
Issue 5 October 2002
The measurements are produced by a set of analog trunk tests. The tests are
initiated by a maintenance demand test or by a set of scheduled tests. The largest
portion of these measurements are generated through scheduled testing during
system quiet hours (hours where the traffic volume is low). Each trunk test
performed by the system stores the results in a database. The trunk
measurements in this database reflect the state of each trunk at the time of its last
test.
Examples
list testcalls detail
list testcalls detail print
list testcalls detail grp 78
list testcalls detail grp 78 result marg count 3 schedule
Action/
Object
Qualifiers/Options
Qualifier/Option Description
list
testcalls
detail
summary
Detailed measurement report displayed
Summary measurement report displayed
grp group number
Measurements for a specific trunk group displayed. When used with
the to-grp option, this option is the starting trunk group in a range of
user-specified trunk groups.
to-grp group number
Measurements for all trunk groups from 1 to the specified “to-grp”
trunk group are displayed. When used with the grp option, this option
is the ending trunk group in a range of user-specified trunk groups.
mem member number
Measurements for a specific trunk group member displayed. When
used with the to-mem option, this option is the starting trunk group
member in a range of user-specified trunk group members.
to-mem member number
Measurements for all trunk group members from 1 to the specified
“to-mem” trunk group member displayed. When used with the mem
option, this option is the ending trunk group member in a range of
user-specified trunk group members.
port location
Measurements for a specific trunk circuit (port) displayed
result result identifier
This option is used to filter out all measurement results that do not
match the user-specified result, that is, only measurement results
that match the user specified result are displayed. Examples of
results are pass, marg, fail, etc.
not-result result identifier
This option is used to filter out all measurement results that do match
the user-specified result, that is, only measurement results that do
not match the user specified result are displayed. Examples of
results are pass, marg, fail, etc.
count count number
This option is used to specify (limit) the number of records displayed.
Report sent to printer
schedule
Use the screen to schedule execution of the command. The
command is placed in the command queue and is executed at the
specified time. The information displayed by the command is sent to
the system printer instead of the screen.
1
1
See the Report Scheduler and System Printer feature specification for more details.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...