MEDPROPT (TN802/TN2302 MED PRO DSP PORT)
Issue 5 October 2002
1391
555-233-119
TDM NIC Looparound Test (#1380)
This test is non-destructive
This test sets up a loopback path from the TDM bus out to the NIC edge of the
Media Processor and back to the TDM bus. The loopback is established by
setting up the outbound IP connection to send IP packets to the MedPro’s own IP
address. The tone generator places a test tone (440Hz) onto a timeslot. The
timeslot is listened to by the Media Processor board. The tone is routed through
the TAP802/2302 DSP farm, where it may undergo transcoding to G.723, etc. The
tone is looped back at the Network interface and back through the TAP802/2302
where it is converted back into standard PCM. The tone is placed onto a TDM
timeslot and detected by a tone detector port. The test passes if 440Hz is reported
by the tone detector
Table 361.
TDM NIC Looparound Test (#1380)
Error
Code
Test
Result
Description/ Recommendation
1002
ABORT
The system could not allocate timeslots for the test. The system may
be under heavy traffic conditions or it may have timeslots out of
service due to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, retry the command at 1-minute intervals a maximum of 3
times.
2. If system has TDM-BUS errors, clear any errors, and retry the
command at 1-minute intervals a maximum of 3 times.
3. If the command continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors. Even if there are no TTR-LEV
errors, there may not be a Tone Detector available on the network
that contains the circuit pack being tested. Verify that there is at
least one Tone Detector on this network. This does not harm the
system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals
a maximum of 3 times.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...