ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 5 October 2002
781
555-233-119
2060
ABORT
Packet-bus link has failed.
Retry the command up to 3 times at 1-minute intervals.
If the test continues to abort, run display errors, and perform the repairs
associated with PKT-INT errors.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error
Retry the command up to 3 times at 1-minute intervals.
1
FAIL
Test tone not detected over the looparound; packet-path test aborted.
Test the active tone clock on the port network, and verify that a tone is
reaching the ATM-TRK circuit pack. If not, correct the condition.
Run test board UUCSS long.
If the test continues to fail, replace the ATM-TRK circuit pack or transceiver.
Rerun test board UUCSS long.
2
FAIL
TN1655 Packet Interface circuit pack could not detect the correct data packet.
Test the TN1655 Packet Interface circuit pack to verify that it is functioning
properly. If not, correct the condition.
Run display errors, and perform the repairs associated with DS1 CONV-BD
errors, if applicable.
Run display alarms, and perform the repairs associated with DS1 CONV-BD
alarms, if applicable.
Run test board UUCSS long.
If this test continues to fail, replace the ATM-TRK circuit pack.
Run test board UUCSS long.
3
FAIL
Distorted tone returned
Test the active tone clock on the port network, and verify that a tone is
reaching the ATM-TRK circuit pack. If not, correct the condition.
Run test board UUCSS long.
If the test continues to fail, replace the ATM-TRK circuit pack.
Run test board UUCSS long.
4
FAIL
Unable to create TDM-path loop.
Retry the command up to 3 times at 1-minute intervals.
If this test continues to fail, replace the ATM-TRK circuit pack.
Run test board UUCSS long.
Table 103.
ATM Board Framer Looparound Test (#1260) —
Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...