ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 5 October 2002
673
555-233-119
1008
ABORT
Could not allocate a ringing circuit for one of the following reasons:
■
All the ringing circuits are in use, or
■
The ringing generator is defective, or
■
It is not wired correctly.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error
Log. If an ABORT 1008 occurs for Test #48 on other circuit packs as
well, the ring generator may be defective. If it does not occur on other
ports, that circuit pack is currently using all 4 ringing phases.
1018
ABORT
Test has been disabled via administration. The default for the
Test
field
on the Station screen is y. Determine why this field has been set to
n
for
this station. It may be due to application Test #48, which can disturb users
or terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Test
field to y.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
System resources required to run this test are not available. Either a
system allocation to get information about the port or to put the port into a
service state failed or the attempt to put the port in connection with a tone
source failed (this could be a tone-clock problem). The tone-clock and tone
detectors could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The terminal equipment is not connected to the circuit pack or the ringing
generator may have failed.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, refer to the RING-GEN (analog ring generator) Maintenance
documentation.
3. Check all of the wiring between the station equipment and the switch,
and run the test again.
4. If the test still fails, the set may be defective. Check the set, and
replace it, if necessary.
5. Some terminal equipment (such as a modem) could fail even when it is
connected properly. If this is the case, use change station extension
and enter n in the Test field to disable the test. This also disables tests
6, 7, 161, 47, and 35 on this port in some systems.
Table 49. TEST #48 Station Present Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...