CO-DS1 (DS1 CO Trunk)
Issue 5 October 2002
909
555-233-119
DS1 CO Dial Tone Seizure Test (#314)
DS1CO Dial Tone Seizure Test checks the trunk’s signaling capability provided by
the DS1 Interface circuit pack. The maintenance software initiates the test by
sending a “seizure” message to the DS1 Interface circuit pack and expects an
“active” reply from the DS1 interface circuit pack. If the “active” message is
received, the test passes. If no message is received and the timer expires, the test
is aborted. If the DS1 Interface circuit pack sends a “reorder” message back to
maintenance software, the test fails.
The test CANNOT be run on a trunk if one of the following cases is true:
a. The trunk direction is administered as an incoming only trunk.
b. The trunk has been seized by a normal trunk call.
c. The trunk is administered with maintenance test disabled.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, an insane board is inserted, or the board is hyperactive
(see note below).
1. Check to ensure that the board translations are correct. Use list config
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long.
This should re-establish the linkage between the internal ID and the port. If
this is not the case, dispatch to check to ensure that there is a valid board
inserted.
Hyperactivity causes some special problems with the sequence suggested
above. If the ports are translated after issuing list config, but the
Vintage
field reports that there is no board when there really is a board, busyout
board and release busy board will not work even though the reset board
works. The software puts the hyperactive board back in service after the
hyperactivity clears.
Table 157.
TEST #36 Port Audit and Update Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...