555-233-119
972
Issue 5 October 2002
1000
ABORT
For this test, an Error Code of 1000 can have one of several different
meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. System resources required to run this test are not available.
c. Internal system error
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Journal Printer Link, PMS Link, or
secondary administration terminal connection) as described previously in
the
‘‘Status of Data Channels’’
section. If so, check for errors on the function
that is using the DATA-CHL. If there are no errors, there is a high probability
that the DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely
test the target DATA-CHL:
1. If the target DATA-CHL is in use for some other function, busyout the
function (PRI-CDR/SEC-CDR, SYS-PRNT, PMS-PRNT/JNL-PRNT,
PMS-LINK) or the DATA-CHL (secondary administration terminal
connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Restore any busied out PRI-CDR/SEC-CDR, SYS-PRNT,
PMS-PRNT/JNL-PRNT, PMS-LINK MOs to service before moving on to
another activity.
1006
ABORT
For this test, an Error Code of 1006 can have one of several different
meanings:
a. System resources required to run this test are not available.
b. Internal system error. Retry the command at 1-minute intervals a
maximum of 5 times.
1016
ABORT
Resources for the test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018
ABORT
Test disabled via software patch.
2000
ABORT
Internal system error
2003
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 177.
TEST #111 Data Channel Local Loop Back Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...