ISDN-TRK (DS1 ISDN Trunk)
Issue 5 October 2002
1309
555-233-119
ISDN-PRI Trunk Service States
The following chart summarizes each of the different DS1 ISDN Trunk service
states that can result when the status trunk <trunk_group/trunk_member>
command is issued.
NOTE:
Refer to
‘‘Troubleshooting Features’’
in
Chapter 1, ‘‘Maintenance for CSI
systems’’
for a layered approach to processing ISDN-PRI problems.
Table 315.
ISDN-PRI Trunk Service States (Test #161 Loop Around Test)
Service State
Alarm*
Possible Cause
Possible Solution
out-of-service/NE
Warning
Trunk is demand busied out.
Enter release trunk
grp#/mbr#.
Minor
NPE Crosstalk Test (#6)
failed.
Replace DS1/UDS1 circuit
pack.
None
DS1 or UDS1 circuit pack
lost its signal.
Is the DS1/UDS1 circuit pack
or cable removed? Is the
far-end switch restarting?
Check circuit pack using
procedures in DS1-BD or
UDS1-BD.
out-of-service/FE
Warning
Unadministered far-end
Administer corresponding
trunk on far-end switch.
Warning
The far-end trunk is busied
out.
Check the status of the
far-end switch.
pending-in-service,
pending-maint
None
Maintenance message was
sent and the switch is
waiting up to 2 min. for a
reply from the far-end.
Wait 2 minutes and check
service state after the
pending state has cleared.
maint-NE
None
ISDN test call in progress
(test trunk long and test
isdn-testcall commands)
Wait several minutes for test
to finish and check status
again.
None
System link has been busied
out by command.
Check link status. Release
link with release link link#.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...