ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 5 October 2002
631
555-233-119
ADX16A-PT (AUDIX Analog
Line/Control Link)
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow
instructions in the
‘‘Power Down AUDIX System’’
section in
Chapter 1,
‘‘Maintenance for CSI systems’’
.
The ADX16A-PT maintenance object represents a port on a TN566/TN2169
EMBEDDED AUDIX circuit pack that is operating in control-link (CL) mode. For
circuit-pack-level problems (ADX16A-BD or ANL-16-BD), see “XXX-BD (Common
Port Circuit Pack)”. For port-level problems with AUDIX operating in digital-port
mode, see ADXDP-PT/ADX8D-PT.
The tests described in this section apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction Board
(MFB) and the TN2169 Alarm Board (ALB). Because of its size this combination
occupies 5 slots, but only 1 slot is functional as far as the switch is concerned. The
other 4 slots are seen by the switch as ‘‘AUDIX-reserved’’ slots.
In CL mode the TN566 pack supports up to 16 voice ports. When a call to a
station with an AUDIX login is not answered, AUDIX answers the call using one of
the available voice ports.
Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command To
Run
1
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01,
02, etc.); and pp is the 2-digit port number (for example, 01).
Full Name of MO
ADXCL-PT or
ADX16A-PT
MINOR
test port PCSSpp l
AUDIX Analog Line/ Control Link
ADXCL-PT or
ADX16A-PT
WARNING
test port PCSSpp sh
AUDIX Analog Line/ Control Link
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...