Maintenance Objects
555-233-119
766
Issue 5 October 2002
22
High-level Path
Alarm Indication
Signal:
HP_AIS
The payload is invalid.
Make sure the ATM switch port (or a MUX port, if present between
ATM switch and the ATM-TRK board) is the same as the ATM-TRK
circuit pack’s cable interface.
Run test board UUCSS.
If Test #1259 fails with Error Code 22, connect a fiber back-to-back
in a looped mode (one strand of fiber connecting the transmit
transceiver to the receive transceiver of the board) and see if the
yellow LED flash goes away.
If it does the problem is off-board.
If the yellow LED continues to flash, replace the circuit pack.
23
High-level path
Remote defect
Indicator: HP_RDI
The far-end is detecting a major problem with the signal that this
board is transmitting. The transmitted payload is invalid.
Make sure the ATM switch port (or a MUX port, if present between
ATM switch and the ATM-TRK board) is the same as the ATM-TRK
circuit pack’s cable interface.
Run test board UUCSS command; if the Test #1259 fails with Error
Code 23, connect a fiber back-to-back in a looped mode (one strand
of fiber connecting the transmit transceiver to the receive
transceiver of the board) and see if the yellow LED flash goes away.
If it does the problem is off-board.
If the yellow LED continues to flash, replace the circuit pack.
24
Loss of cell
delineation (LCD)
On board ATM framer chip is not able to frame cells based on the
cell header.
Reset the board (reset board UUCSS).
If the error persists, replace the board.
27
SIGCON_DOWN
ATM switch high
level signal.
The board cannot communicate with the ATM switch.
Busyout the board (busyout board UUCSS).
Test the board (test board long UUCSS).
If Test #1260 fails, replace the board.
If Test #1260 passes, make sure the ATM address on both the
Avaya Definity Server CSI and the ATM switch sides are the same
for this board.
If the address is the same, change the port on the ATM switch side.
If the error is resolved, the problem is on the ATM switch port.
Table 94.
Error type 1281 Aux Data and repair procedures —
Continued
Aux
Data
Alarm
Description
Repair procedure
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...