TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Issue 5 October 2002
1629
555-233-119
i. Error Type (1538): This error occurs when a frame with a bad CRC is
received by the BRI trunk board. This error only occurs on a system that
switches the packet implementation of the D-channel over the TDM bus.
This error indicates an off board problem related to the packet
implementation of the TDM D-Channel.
j. Error Type (1793): The BRI Port Local TDM Loop Around Test (#619)
failed. Run the Long Test Sequence paying particular attention to the
results of the BRI TDM Port Loop Test (#619).
k. Error Type (2049): The Layer 2 Link Query failed. The test is repeated
every 15 minutes until it passes.
l. Error Type (2305): The Remote Layer 3 Query failed. The test is repeated
every 15 minutes until it passes.
m. Error Type (3073): A frame of information had to be repeated or deleted.
Slips usually occur when the received bit rate is not synchronized with the
TDM Bus clock.
n. Error Type (3585): The circuit pack detected an overflow of its receive
buffers. This error occurs only a system that switches the packet
implementation of the D-Channel over the TDM bus. This error indicates an
on board problem related to the packet implementation of the TDM
D-Channel.
o. Error Type (3586): Each port can support up to three Terminal Endpoint
Identifiers (TEIs). Each channel on the port can request a TEI assignment
from the switch if it supports ISDN-BRI TEI assignment procedures. If
switch services gets a request for a fourth TEI on a port, it reports this
event to maintenance software and initiates TEI check procedures on the
port. Check to see if the correct number of channels are administered for
this port.
The user side supports automatic TEI assignment by the network. Both
fixed and automatic TEI assignment are supported on the network side.
p. Error Type (3587)Service Profiler IDentifier (SPID) value is invalid or is a
duplicate of another SPID that is already initialized at Layer 3 on the port.
SPIDs are not used on the TN2185 circuit pack. However there will be
related events.
q. Error Type (3588): The board receives D-Channel data from the bus faster
than it can process the data. The FIFO RAM buffers overflowed. This error
occurs occasionally due to the statistical sizing of the buffers; however,
frequent occurrences may indicate a LAPD parameter mismatch between
the two endpoints of a packet-switched connection. Run the Long Test
Sequence paying particular attention to the results of the Receive FIFO
Overflow Test (#625).
r. Error Type (3589): The BRI Port Local LAN Loop Around Test (#618) failed.
Run the Long Test Sequence and pay particular attention to the results of
Test #618.
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...