Maintenance Objects
1794
Issue 5 October 2002
1324
FAIL
A non-service-affecting CSU Module/Sync Splitter audit failure was detected
by the UDS1 circuit pack. No ports should be affected. No immediate action
is required. These errors indicate that the CSU Module/Sync Splitter
hardware may have a problem, and that it should be replaced when practical
to avoid further deterioration.
1400
FAIL
Echo Canceller Function failed, this could be a hardware problem on the
TN464GP/TN2464BP:
1. Issue the busyout board command.
2. Issue the test board long command.
3. Issue the release board command.
4. If Test 1420 still fails, replace the TN464GP/TN2464BP.
1401
FAIL
Echo Canceller Function failed, this could be a hardware problem on the
TN464GP/TN2464BP:
1. Issue the busyout board command.
2. Issue the reset board command.
3. Issue the test board long command.
4. Issue the release busy board command.
5. If the test still fails replace the TN464GP/TN2464BP.
PASS
DS1 signal is present and the physical link is healthy. In addition, no
Integrated CSU/Sync Splitter errors or echo cancellation errors are detected.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 530.
TEST #138 Loss of Signal Alarm Inquiry Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...