CO-TRK (CO Trunk)
Issue 5 October 2002
927
555-233-119
FAIL
Failure to detect ground or faulty ground detected on Ring lead. Display the
hardware errors for this trunk, to determine if the fault was on- or-off board.
Look for Error Type 1025 or 1281 (if both appear in the Hardware Error
Log, pick the most recent error). Error Type 1025 indicates a faulty ground
detected on Ring lead (an off-board fault) and Error Type 1281 indicates
failure to detect (internally generated) ground (an on-board fault). Faulty
ground detected on Ring lead (Error Type 1025):
NOTE:
On TN747B vintage 8 and greater circuit packs, an incoming seizure
during this test may cause it to fail with an off-board fault.
1. Repeat test. If test passes, ignore the original failure. If test aborts,
follow the recommended procedures.
2. Repeat test with CO line removed.
3. If test fails, replace the circuit pack.
4. If test passes, refer problem to CO.
Failure to detect ground (Error Type 1281):
1. Run the long test sequence. If the CO Demand Diagnostic Test fails,
the Dial Tone Test (#0) fails with Error Code 2002, AND Error Type
3329 or 3585 appears in the Hardware Error Log (with the same last
occurred time as Error Type 1281 and 1537), replace the circuit pack.
2. Repeat test with CO line removed.
3. If test fails, replace the circuit pack.
4. If test passes, the CO may be drawing too much current. Refer
problem to CO.
57481
FAIL
On-board test of programmable transmission circuitry failed.
1. Replace the circuit pack.
PASS
This test verifies that the port is able to apply ground for outgoing calls and
detect ground for incoming calls; however, it does not provide information
on whether a CO line is actually connected. User-reported troubles on this
port should be investigated by using other port tests and by examining
trunk or external wiring.
Table 162.
TEST #3 CO Demand Diagnostic Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...