Maintenance Objects
555-233-119
910
Issue 5 October 2002
Table 158.
TEST #314 DS1CO Dial Tone Seizure Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
The test was aborted because system resources required to run this test
were not available. The port may be busy with a valid call. Use display port
PCSSpp to determine the trunk group/member number of the port. Use
status trunk to determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for certain tests. Wait
until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1004
ABORT
The test was aborted because the port was seized by a user for a valid call.
Use display port PCSSpp to determine the trunk group/member number of
the port. Use status trunk to determine the service state of the port. If the
service state indicates that the port is in use, the port is unavailable for
certain tests. Wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1005
ABORT
Test failed due to incompatible configuration administered in trunk group
form.
1. Verify the following fields on the trunk group administration screen: Is
trunk direction incoming only? Is trunk the port 24 of the DS1 Interface
circuit pack while common control channel signaling is specified? Is
trunk group type the automatic CO (for example, FX)?
2. If the trunk has been administered using the above information, this test
should abort.
1018
ABORT
The test is disabled via translation. You may want to determine why the test
has been disabled before you enable it.
1. Verify that the
Maintenance Test
field on the Trunk Group form is
set to n. To enable the test, issue change trunk-group x where x
equals the number of the trunk group to be tested. Set the
Maintenance Test
field to y.
2. Repeat the test.
Continued on next page
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...