test alarms
Issue 5 October 2002
529
555-233-119
Output
The following example shows the output from test alarms (query screen left
empty by pressing
ENTER
). The responses appear on a test-by-test basis with one
line of data for each test result.
From
Test alarm from the specified time specified (mm/dd/hh/mm). If no
from
date is entered, then no checking is done and the alarms
active since a month prior to the current time are reported.
To
Test alarms associated with records to the specified time specified
(mm/dd/hh/mm). If no
to
date is entered, any alarm active after the
from
date is selected.
Equipment
Type
If these fields are blank, the system defaults to all of the equipment.
Select one of the following fields:
■
Cabinet
: tests alarms associated with a particular cabinet (1-3).
■
Port Network
: tests all alarms associated with a particular port
network (1-3).
■
Board Number
: tests all alarms associated with a particular
circuit pack (PCSS, default cabinet = 1).
■
Port
: tests all alarms associated with a particular port on a
circuit pack (PCSSpp, default cabinet = 1).
■
Category
: Alarms for a particular equipment category
■
Extension
: Alarms associated with an extension number
■
Trunk
(group/member): tests all alarms associated with a
particular trunk group or trunk group member, XX/YY, where the
group identifier tests all alarms associated with a trunk group
(XX/__), and the group identifier and member identifier are both
entered to test all alarms associated with a specific trunk group
member (XX/YY).
Содержание DEFINITY Server CSI
Страница 1: ...Maintenance for Avaya DEFINITY Server CSI Volumes 1 and 2 Release 1 2 555 233 119 Issue 5 October 2002...
Страница 6: ......
Страница 20: ...Contents 555 233 119 20 Issue 5 October 2002...
Страница 30: ...About this Book 555 233 119 30 Issue 5 October 2002...
Страница 944: ...Maintenance Objects 555 233 119 944 Issue 5 October 2002...
Страница 1397: ...MMI BD Issue 5 October 2002 1397 555 233 119 Figure 44 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1409: ...MMI PT Issue 5 October 2002 1409 555 233 119 Figure 45 TN787 Multimedia Interface MMI Circuit Pack...
Страница 1891: ...VC DSPPT Issue 5 October 2002 1891 555 233 119 Figure 63 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 1902: ...Maintenance Objects 1902 Issue 5 October 2002 Figure 65 VC Circuit Pack Summer Port Loopback Test...